NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
Connect Remote server
claude mcp add --transport http nec-calculators https://sparkquote.ai/mcp
{
"mcpServers": {
"nec-calculators": {
"url": "https://sparkquote.ai/mcp"
}
}
}
{
"servers": {
"nec-calculators": {
"type": "http",
"url": "https://sparkquote.ai/mcp"
}
}
}
Settings > Connectors > Add custom connector
URL: https://sparkquote.ai/mcp
Tools 10 found in our last check
wire_sizeMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop…
voltage_dropVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).
watts_to_ampsCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.
conduit_fillPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.
box_fillMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.
load_calculatorDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.
ohms_lawOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.
panel_scheduleLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.
bid_calculatorElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).
nec_ampacityAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.
Details
| Endpoint | https://sparkquote.ai/mcp (Streamable HTTP) |
| First published | 14 Oct 2026 |
| Last updated | 14 Oct 2026 |
| Registry name | ai.sparkquote/nec-calculators |
More other servers See all
Listing data from the official MCP registry. Status and tools from NestDaddy's daily check. Browse all MCP servers.