NestDaddy

The Grate Guys Tools

com.thegrateguys/tools ยท v1.0.0

Planning calculators for metal grating, drainage covers and fabrication.

MCP Score How we grade

A+
96 / 100

From what our daily checks can see without credentials, last checked 22 Nov 2026.

Reliability
Answered 6 of 6 daily checks.
30 / 30
Speed
Typical response 122 ms.
20 / 20
Tool docs
15 of 15 tools have a full description; 107 of 107 inputs have a description.
25 / 25
Stability
No tool rewrites in 30 days.
15 / 15
Listing
Missing a source or website link, an icon.
6 / 10

How to raise the grade

  • Add a source or website link, an icon to your server.json in the official MCP registry.
Fixed something? Run the same check now. The grade updates at once.

Connect Remote server

Terminal
claude mcp add --transport http tools https://thegrateguys.com/mcp
~/.cursor/mcp.json
{
  "mcpServers": {
    "tools": {
      "url": "https://thegrateguys.com/mcp"
    }
  }
}
.vscode/mcp.json
{
  "servers": {
    "tools": {
      "type": "http",
      "url": "https://thegrateguys.com/mcp"
    }
  }
}
Claude Desktop
Settings > Connectors > Add custom connector
URL: https://thegrateguys.com/mcp

Tools 15 found in our last check

  • bar_grating_load_calculator

    Finds the lightest welded steel bearing bar (19-W-4 or 15-W-4, smooth or serrated) that carries a clear span and load within a deflection limit.

  • bar_grating_load_tables

    Looks up the safe uniform load (U), safe concentrated load (C), deflections and weight for welded steel bar grating by bearing bar size and span.

  • aluminum_stainless_bar_grating_load_calculator

    Safe load, deflection and the lightest bearing bar for aluminum 6063-T6 and stainless 304, 316, 304L and 316L bar grating at 1-3/16 in bar centres.

  • accessible_grating_opening_checker

    Checks the clear opening between bearing bars against the Ontario Building Code 13 mm limit for barrier-free paths of travel, and the widest bar spacing that would pass.

  • galvanizing_coating_thickness_calculator

    Minimum average hot-dip galvanized coating grade by steel category and thickness, in mils, microns and ounces of zinc per square foot, with total zinc for a surface area.

  • guard_and_railing_code_checker_ontario

    Whether a guard is required, its minimum height, opening limit, climbing rule and design loads under the Ontario Building Code Part 9 and Part 3 for a described situation.

  • steel_stair_calculator_ontario

    Allowed riser counts, riser height, tread run, flights, width, headroom and handrail height for a total rise under Ontario Building Code Part 9.

  • steel_weight_calculator

    Theoretical weight of carbon steel plate, flat bar, round bar, square bar, angle, square or rectangular tube and round pipe, in pounds and kilograms.

  • trench_drain_grate_load_class

    The EN 1433 load class, A 15 to F 900, and its test load in kN for where a trench drain goes and what drives or rolls over it.

  • bollard_spacing_and_footing_calculator

    Counts the bollards for a frontage and clear gap, checks the gap against vehicle and wheelchair guidance, gives typical footing and concrete for a standard (not crash rated) steel pipe bollard, and explains crash ratings.

  • steel_beam_lintel_span_check

    The steel angle lintel or steel beam that the 2024 Ontario Building Code Part 9 tables list for an opening width in a brick or stone veneer wall or a masonry wall, with the 150 mm bearing rule. Not a stamped design.

  • catch_basin_grate_and_frame_size_finder

    Names the Ontario Provincial Standard Drawing for a catch basin inlet type, checks the grate bearing on the frame ledge against the NAAMM minimum, gives the range of bearing bar lengths that sit on the ledge, and lists the EN 1433 load class for the traffic.

  • fence_and_gate_post_spacing_and_weight

    Post count and spacing for a chain link or ornamental steel fence run, chain link footing depth and gate post size, and the weight and hinge loads of an ornamental steel gate leaf.

  • trench_drain_flow_capacity_calculator

    The flow a trench drain has to handle from a paved area (rational method with Toronto City rainfall rates from Environment and Climate Change Canada) and the flow the channel carries (Manning), with the narrowest channel that works.

  • loading_dock_height_and_leveler_check

    The grade a dock leveler works at between the lowest and highest truck bed you serve, against the 10% (electric) and 15% (gas or diesel) limits, the shortest standard leveler length that fits, and whether two makers published working ranges cover it.

Details

Endpointhttps://thegrateguys.com/mcp (Streamable HTTP)
First published16 Nov 2026
Last updated16 Nov 2026
Registry namecom.thegrateguys/tools

More developer tools servers See all

Listing data from the official MCP registry. Status and tools from NestDaddy's daily check. Browse all MCP servers.