PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.
Connect Remote server
claude mcp add --transport http pt-chart-mcp https://pt-chart-mcp-production.up.railway.app/mcp
{
"mcpServers": {
"pt-chart-mcp": {
"url": "https://pt-chart-mcp-production.up.railway.app/mcp"
}
}
}
{
"servers": {
"pt-chart-mcp": {
"type": "http",
"url": "https://pt-chart-mcp-production.up.railway.app/mcp"
}
}
}
Settings > Connectors > Add custom connector
URL: https://pt-chart-mcp-production.up.railway.app/mcp
Tools 8 found in our last check
pt_lookupSaturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superhe…
pt_reverseSaturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for sup…
superheatSuperheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target:…
subcoolingSubcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target:…
convert_unitsConvert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).
refrigerant_infoReference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only.
diagnoseConversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to d…
coolbooked_infoAbout CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings.
Details
| Endpoint | https://pt-chart-mcp-production.up.railway.app/mcp (Streamable HTTP) |
| First published | 18 Oct 2026 |
| Last updated | 18 Oct 2026 |
| Registry name | io.github.Tsonnn/pt-chart-mcp |
More other servers See all
Listing data from the official MCP registry. Status and tools from NestDaddy's daily check. Browse all MCP servers.
