NestDaddy

uniwire

io.github.uniwire-dev/uniwire · v0.1.8

Electrical single-line and multi-line diagrams: build, check (NF C 15-100, IEC 60364), draw, PDF.

Connect Remote server

Terminal
claude mcp add --transport http uniwire https://mcp.uniwire.sh/mcp
~/.cursor/mcp.json
{
  "mcpServers": {
    "uniwire": {
      "url": "https://mcp.uniwire.sh/mcp"
    }
  }
}
.vscode/mcp.json
{
  "servers": {
    "uniwire": {
      "type": "http",
      "url": "https://mcp.uniwire.sh/mcp"
    }
  }
}
Claude Desktop
Settings > Connectors > Add custom connector
URL: https://mcp.uniwire.sh/mcp

Tools 14 found in our last check

  • get_reference_card

    Return the reference card of the uniwire format for electrical diagrams: document skeleton, node types (breakers, RCDs, cables, loads, transformers, PV...) and their fields, enums, links, pitfalls, examples. Read it once before writing a document; type_info gives the fields of o…

  • list_types

    List the node types of the format (type, category, label), optionally for one category. Use it to find the type name of a device or load before writing a node; type_info then gives its fields.

  • type_info

    Return every field of one node type with its description, unit and allowed values (enums). Use it before writing or editing a node of that type; list_types gives the type names.

  • validate

    Validate a uniwire document (electrical diagram as JSON) against the format only: structure, types, ids, references and links, without the electrical rules (use check for those). Returns valid + issues, each naming the node id and field when possible, plus viewer_url (the docume…

  • check

    Check an electrical installation (single-line diagram, panel, schéma unifilaire, tableau électrique): validates the document, then applies the rule profiles (NF C 15-100 'nfc15100', French grid connection 'enedis', IEC 60364 'iec60364', PLC; default: the document's 'profiles'; '…

  • describe

    Return a text outline of an electrical diagram: installation, full tree of the panel with stable ids, ratings and cables, links, interlocks, boards and findings summary. Use it to read a document and find the node ids before apply_patch.

  • apply_patch

    Edit an electrical diagram by node id (change a rating, add a circuit, move a load...) and return the new document. ops (applied in order): {"op":"set","id":ID,"path":"in_A","value":20} (null value removes; no id = document root, e.g. path "installation.earthing"); {"op":"add","…

  • render

    Draw the electrical diagram (schéma unifilaire / multifilaire). kind: 'single-line' or 'multi-line'; view: a view id of the document (e.g. a wire-marking view). format 'svg' returns the SVG text of every sheet (or of 'sheet', numbered from 1); 'pdf' writes to 'path' if given, el…

  • viewer_link

    Links to a document: viewer_url opens it in the uniwire web editor (drawing, single-line and multi-line, rule findings, PDF and SVG downloads, nothing to install); pdf_url is the PDF drawn by uniwire. On the hosted server the document is kept 30 days so that the short links open…

  • wiring

    Wiring exports of an installation as rows with stable column names (repérage des fils, carnet de câbles): what='markers' (one row per wire end, for label printers), 'wires' (wire list) or 'cables' (cable schedule). Marks follow the wire_marking rules of the view (id), by default…

  • bom

    Compute the bill of materials (nomenclature) of an electrical installation from its document: one row per manufacturer / part number for the nodes with a product reference, then one row per kind of equipment without a reference (type and main characteristics in 'spec', e.g. 'C16…

  • list_examples

    List the 53 example installations (dwellings, shops, offices, workshops, PV, EV charging, UPS, MV/LV substations, PLCs): name, title, language, profiles, earthing, system.

  • get_example

    Return an example installation document by name. Use it as a starting point for a similar installation, then edit it with apply_patch; list_examples gives the names.

  • normalize

    Return the resolved form of a document: templates ('use') applied, every node and link id assigned, numbers in canonical form. Use it to read a document exactly as the rules and drawings see it, or to get stable ids before apply_patch; it does not apply the electrical rules (see…

Details

Endpointhttps://mcp.uniwire.sh/mcp (Streamable HTTP)
First published2 Nov 2026
Last updated2 Nov 2026
Registry nameio.github.uniwire-dev/uniwire

More files and documents servers See all

Listing data from the official MCP registry. Status and tools from NestDaddy's daily check. Browse all MCP servers.